AR9000 DSM2 9-Channel Receiver
BulletinsSpektrum AR9000 Service BulletinHigh Vibration Fatigue: Recently we’ve received three reported cases of AR9000 receivers failing when being used in high vibration applications. All failures occurred in Spektrum team member’s 90-size glow helicopters mounted with minimal or no vibration isolation. In all three cases, the leads of the electrolytic can style capacitor on the base PCB experienced vibration fatigue and failure. Our staff is reworking all AR9000s in our stock to bond the capacitor to the PC board to eliminate any movement under vibration loads. All shipments as of 08/14/07 will be corrected and marked. For customers that already have AR9000 receivers it’s highly recommended that you return your AR9000 to our Spektrum service center and we will promptly correct the issue. If you feel confident in doing so, follow the instruction below to bond the capacitor to the PC board.
Step 1:
Step 2:
Step 3:
Step 4: Manuals
Product SupportTechnical Questions: Questions about this product should be directed to
Horizon Hobby's Product Support department.
• |
|
|
Copyright 2nd RC Flight School 2003 - 2008...This site was last updated 12/08/07 |